Online Champ RM 1K VA/900W Rackable
Technologie ON-Line
Puissance en VA 1000 VA
Puissance Watt 900W
Nombre de prises 2
Rack Oui

•True double-conversion
•Microprocessor control optimizes reliability
•Input power factor correction
•Output power factor 0.9
•Wide input voltage range
•Converter mode available
•ECO mode for energy saving only available for 1-3KVA models
•Generator compatible
•Adjustable charging current via LCD or software (1A~6A)
•Emergency power off function (EPO) only available for 6K/10K models
•Comprehensive display allows easy monitoring and access of UPS status
Frequency Range
AC Mode to Battery Mode
Inverter to Bypass
Battery Type
Numbers
Typical Recharge Time
Charging Current (max.)
Charging Voltage
Battery Type
Numbers 2 3 4 6 8 6 8
Charging Current (max.)
Charging Voltage 27.4VDC ± 1%41.0VDC ± 1%54.7 VDC ±1%82.1 VDC ±1%109.4VDC ±1%82.1 VDC ±1%109.4VDC ±1%
Dimension, D x W x H (mm)
Net Weight (kgs)
Dimension, D x W x H (mm)
Net Weight (kgs)
* Product specifications are subject to change without further notice
Noise Level
BATTERY
Standard 410 x 438 x 88
Model
Standard
Model
PHYSICAL
20-90 % RH @ 0- 40°C (non-condensing)
*1K-3K: Derate to 80% of capacity in Frequency converter mode or when the output voltage is adjusted to 208VAC.
6K/10K: Derate to 60% of capacity in Frequency converter mode and to 80% when the output voltage is adjusted to 208VAC.
14.2
410 x 438 x 88
630 x 438 x 88
29.3
Less than 50dBA @ 1 Meter
12 V / 9 AH 12 V / 9 AH
4
Depending on the capacity of external batteries
Optional SNMP
Single phase with ground
12
Overload
9
LCD
Long-run
Model*
PHASE
≧ 0.99 @ Nominal Voltage (100% load)
3:1
47~ 53 Hz or 57 ~ 63 Hz
110/115/120/127VAC or 208/220/230/240VAC
Champ 1KR
90%
Zero
Battery Mode
88%
12 V / 9 AH
6
54.7 VDC ±1%
1A/2A/4A/6A (Adjustable)
27.4VDC ± 1%
INDICATORS
ENVIRONMENT
MANAGEMENT
89%
12
Battery Mode
2
88%
Long-run
Model*
310 x 438 x 88
310 x 438 x 88
Fault
82.1 VDC ±1%
4 hours recover to 90% capacity
40Hz ~ 70 Hz
AC Mode
60-145 VAC or 120-300 VAC at 50% load
90-145 VAC or 180-300 VAC at 100% load
Pure Sinewave
83% 87%
1.0 A
Waveform (Batt. Mode)
Frequency Range (Batt. Mode)
4 ms (Typical)
Input Voltage Range
110/115/120/127VAC or 208/220/230/240VAC
Power Factor
Current Crest Ratio
≦ 3 % THD (Linear Load)
≦ 6 % THD (Non-linear Load)
Frequency Range (Synchronized Range)
Champ 3KR
CAPACITY 1000 VA / 900 W 2000 VA / 1800 W
Output Voltage
MODEL Champ 2KR
3000 VA / 2700 W
INPUT
Nominal Voltage
Smart RS-232/USB
Humidity
19
Low Battery
OUTPUT
Harmonic Distortion
Voltage Regulation ± 1%
50 Hz ± 0.25 Hz or 60Hz ± 0.3 Hz
Transfer
Time
Load level, Battery level, AC mode, Battery mode, Bypass mode, and Fault indicators
Champ RACK ONLINE UPS SELECTION GUIDE
Supports Windows 2000/2003/XP/Vista/2008/7/8, Linux, Unix, and MAC
EFFICIENCY
Power management from SNMP manager and web browser
ALARM
Sounding every 4 seconds
Sounding every second
Sounding twice every second
Continously sounding